MICROWAVE · INSTRUMENTS · BOARDS · MODULESgeorge@hportek.com

Vector Network Analyzers

SYVNA-2P-M20GDual-Port Vector Network Analyzer

The SYVNA-2P-M20G is a low-cost, high-performance, compact dual-port VNA covering 10 MHz to 20 GHz. It offers bench-level performance with open interfaces for secondary development, suitable for laboratories, research/education, and system integration.

  • Compact, lightweight, low power, portable
  • Multi-site parallel testing
  • LAN interface for secure PC control

TECHNICAL DATA

Technical specifications

Specifications correspond to the product catalogue. Contact our technical team for configuration and operating conditions.

SYVNA-2P-M20G Technical specifications
ParameterSpecification / typical value
Functional Specifications
Independent S-parameter measurementSupported
Swept/fixed-frequency modes; time-domain analysis (cable fault distance, reflection distance)Supported
Measurement, calibration & de-embedding via host softwareSupported
Technical Specifications
Frequency Range10MHz-20GHz
Frequency Accuracy±5×10-6
Frequency Resolution1Hz
Sweep Points2 to 10001 points
Measurement Bandwidth1Hz~300kHz
Dynamic Range≥80dB
Transmission Accuracy±0.2dB/±2°(0dB~10dB);;±0.1dB/±2°(-45dB~ 0dB);;±0.2dB/±2°(-65dB~-45dB);;±1dB/ ±6°(-70dB~-65dB)
Reflection Accuracy±0.5dB/±4°(-15dB~0dB);;±1.5dB/±10°(-25dB~- 15dB);;±5.5dB/±30°(-35dB~-25dB)
Trace Noise0.002dBrms(10MHz~6.5GHz);; 0.003dBrms(6.5GHz~12GHz);; 0.004dBrms(12GHz~20GHz)
Temperature Characteristics0.02dB/℃(10MHz~6.5GHz);;0.04dB/℃(6.5GHz ~20GHz);
Effective Directivity35dB
Effective Source Match30dB
Effective Reflection Tracking±0.5dB
Burn-out Power+25dBm
Ext. Ref. Frequency10MHz
Ext. Ref. Power0dBm~5dBm
Output Ref. Frequency10MHz
Output Ref. Power0dBm~5dBm
General Specifications
Supply Voltage12Vdc
Power Consumption40W
Operating Temperature+5℃~+40℃
Storage Temperature-50℃~+70℃
Relative Humidity90% RH at 25°C
Dimensions (excl. connectors)200mm×156mm×48mm
Weight4kg

Specifications are subject to change without notice. Contact our technical team for full conditions, interface definitions, and ordering information.

Handling notes

  • Take anti-static precautions and ensure device ports are clean before use.
  • Use a torque wrench to tighten coupling nuts where applicable.
  • Check connector pin depth before calibration to avoid damage to calibration devices.