The SYVNA-1P-20G-A is a low-cost, high-performance, compact single-port VNA covering 10 MHz to 20 GHz. It is small enough to connect directly to the DUT for both indoor and outdoor applications, supporting VSWR, phase, impedance measurements, cable fault detection, and non-destructive microwave testing of non-metallic materials.

  • Compact, lightweight, low power, portable
  • Multi-site parallel testing
  • LAN interface for secure PC control

TECHNICAL DATA

Technical specifications

Specifications correspond to the product catalogue. Contact our technical team for configuration and operating conditions.

SYVNA-1P-20G-A Technical specifications
ParameterSpecification / typical value
Functional Specifications
Independent reflection parameter measurementSupported
Swept/fixed-frequency modes; time-domain analysis (cable fault distance, reflection distance)Supported
Measurement & calibration via host softwareSupported
Technical Specifications
Frequency Range10MHz~20GHz
Output Power-45dBm~0dBm(10MHz≤f≤50MHz);-45dBm~ 5dBm(50MHz≤f≤8GHz);-45dBm~0dBm(8GHz< f≤16GHz);-45dBm~-10dBm(16GHz<f≤20GHz)
Min. Time per Point650μs/point (IFBW=10kHz)
Sweep Points2 to 10001 points
Frequency Accuracy±2.5×10-6
Frequency Resolution50Hz
IF Bandwidth10Hz~300kHz
Cable Loss Range30dB
Reflection Coeff. Accuracy±0.5dB/±5°(-15dB~0dB);±1.5dB/±10°(-25dB~- 15dB);±5.5dB/±30°(-35dB~-25dB)
Trace Noise0.010dBrms(IFBW=3kHz)
Effective Directivity35dB
Effective Source Match30dB
Effective Reflection Tracking±0.5dB
Burn-out Power+25dBm
General Specifications
Supply Voltage+12V DC
Power Consumption≤15W
Operating Temperature+5℃~+40℃
Storage Temperature-50℃~+70℃
Dimensions (excl. connectors)≤150 mm (L) × 100 mm (W) × 50 mm (H)
Weight≤0.6kg

Specifications are subject to change without notice. Contact our technical team for full conditions, interface definitions, and ordering information.

SYSTEM ARCHITECTURE

Product block diagrams

SYVNA-1P-20G-A block diagram 1
SYVNA-1P-20G-A / Diagram 1 Open full image ↗

Handling notes

  • Take anti-static precautions and ensure device ports are clean before use.
  • Use a torque wrench to tighten coupling nuts where applicable.
  • Check connector pin depth before calibration to avoid damage to calibration devices.